3A6927C ZH Installation and Operation SDP8/SDP18 Preset Proportioning Valve Pulse FC Enabled

The 3A6927C ZH Installation and Operation SDP8/SDP18 Preset Proportioning Valve Pulse FC Enabled is used to dispense engine oil, automatic transmission fluid (ATF), gear oil and antifreeze. Not approved for use in explosive atmospheres or hazardous locations. For professional use only. Refer to Page 6 for model information. Maximum working pressure 1500 psi (10 MPa, 103 bar)


3A6927C ZH Installation and Operation SDP8/SDP18 Preset Proportioning Valve Pulse FC Enabled - cover page
Brand
Graco
Category
Automotive supplies
Document type
User Manual
Language
Chinese
Pages
44
File format
PDF
File size
6.5 MB
Published
15 November, 2023
Updated
15 November, 2023
MD5 checksum
039FF68936A43D41B9D2B68CF8EB59E9

About this manual

This Graco SDP8/SDP18 preset metering dispense valve is designed for dispensing motor oil, automatic transmission fluid (ATF), gear oil and antifreeze. It has a maximum working pressure of 1500 psi (10.34 MPa, 103.4 bar) and is intended for professional use only; it is not approved for explosive environments or hazardous locations.

The manual covers installation, grounding, preset mode, calibration, dispensing, maintenance, parts, troubleshooting and technical specifications. It also includes information on Pulse FC mode, the navigation panel, and the utility menu. This manual is written in Chinese.

What's inside

  • Warnings
  • Models
  • Overview
  • Installation
  • Preset Mode
  • Calibration
  • Dispensing
  • Maintenance
  • Troubleshooting
  • Technical Specifications

Specifications

Flow range0.25 to 18 gpm (0.9 to 68 lpm)
Maximum working pressure1500 psi (10.34 MPa, 103.4 bar)
Weight5.3 lb (2.4 kg)
Dimensions without extension tube13 x 3.75 x 5.75 in (33 x 9.5 x 14.6 cm)
Inlet1/2-14 NPT or 3/4-14 NPT
Outlet3/4-16 straight thread O-ring boss
Operating temperature range4°F to 158°F (-16°C to 70°C)
Accuracy+/- 0.5%

Frequently asked questions

What fluids can the Graco SDP8/SDP18 valve dispense?

It is used for dispensing motor oil, automatic transmission fluid (ATF), gear oil and antifreeze.

Is the valve approved for use in explosive environments?

No. It is not approved for explosive environments or hazardous locations.

What is the maximum working pressure of the valve?

The maximum working pressure is 1500 psi (10.34 MPa, 103.4 bar).

What type of battery does the valve use?

It uses four AA alkaline batteries; Energizer E91 alkaline is suggested.