This is an installation and operation manual for a water pump.
Waterco pumps are designed for pre-filtering and recirculation of water in swimming pools, using clean water at temperatures not exceeding 35 degrees Celsius (95 degrees Fahrenheit). This manual covers safety rules, location, installation, electrical connection, priming, maintenance, servicing and troubleshooting.
Installation must be performed by a qualified technician, with attention to suction line size, pump mounting, motor grounding, ventilation clearance and required electrical protection. The manual also describes three-phase motor rotation checks, wiring diagrams, priming steps and maintenance precautions.
| Maximum fluid temperature | 35 degrees Celsius (95 degrees Fahrenheit) |
|---|---|
| Minimum suction line size | 40mm (1 1/2 in) |
| Motor cooling fan clearance | 150mm minimum |
| Earth leakage circuit breaker tripping current | Not exceeding 30mA |
| Power cord quality (models greater than 1 kW) | 245 IEC66 (HO7RN-F) |
| Power cord quality (models less than 1 kW) | 245 IEC57 (H05RN-F) |
| Contact distance | 3mm per pole |
| Three-phase motor rotation | Clockwise when viewed from the motor end fan (cowl) cover |
They are designed to work with clean water at a temperature not exceeding 35 degrees Celsius (95 degrees Fahrenheit).
The pump suction line should be not smaller than 40mm (1 1/2 in).
The pump motor cooling fan must have a minimum clearance of 150mm.
An earth leakage circuit breaker with a rated tripping current not exceeding 30mA must be installed.