The Waterco Micron Sand Filter user manual provides installation, operation, backwashing and maintenance instructions for the filtration system.
This manual covers the complete setup of Waterco filtration systems, including sand, D.E. and cartridge filters. It explains safety considerations, proper placement, plumbing, and the installation of the multi‑port valve and filter media.
Operational guidance includes initial startup, backwashing procedures, routine maintenance, and troubleshooting. Specific sections address D.E. filter start‑up, cartridge filter handling, and warranty information.
| Backwash pressure trigger | 50 kPa (7.2 psi) above start‑up pressure |
|---|---|
| Maximum operating pressure (D.E. filter) | 250 kPa |
| Model 2027 weight | 1.5 kg |
When the pressure gauge reads 50 kPa (7.2 psi) higher than the start‑up pressure.
Screw the barrel unions onto the threaded ports on the Multiport Valve, apply Teflon tape, and tighten securely.
The D.E. filter is rated for a maximum operating pressure of 250 kPa.