Fosroc Conbextra EP10 and EP65 Plus Epoxy Grouts Bonded Anchoring Application Guide

Fosroc® Conbextra® Epoxy Grouts is a bonded anchor system for vertical anchoring applications. The system consists of two epoxy resins: Conbextra EP10 and Conbextra EP65 Plus. Both resins have been independently tested and shown to have high pull-out strengths.


Fosroc Conbextra EP10 and EP65 Plus Epoxy Grouts Bonded Anchoring Application Guide - cover page
Brand
Fosroc
Category
Chemical products
Document type
Application Note
Language
English
Pages
2
File format
PDF
File size
105 KB
Published
11 November, 2023
Updated
11 November, 2023
MD5 checksum
F64A86E7F092E7B6850D42E51FE2ADED

About this manual

This two-page application guide describes typical use of Fosroc Conbextra EP10 and Conbextra EP65 Plus as bonded anchors for vertical anchoring applications. It reports independent pull-out strength testing by Swinburne University in concrete, using Grade 8.8 hot dipped galvanised steel all-thread under controlled conditions at 23 °C in 40 MPa design mix concrete cured for 28 days; Conbextra EP10 was tested after 3 days cure, and Conbextra EP65 Plus after 24 hours and 3 days.

The guide covers preparation of the foundation, mixing, placement, and curing and protection. It notes that if any doubt exists on site regarding the product or process, all parties involved should consult and proceed with an agreed plan, and it includes safety and product disclaimer notices.

What's inside

  • Introduction
  • Preparation of the foundation
  • Mixing
  • Placement
  • Curing and Protection
  • Important notice
  • Product disclaimer

Specifications

Test concrete design mix40 MPa
Test temperature23 °C
Test anchorGrade 8.8 hot dipped galvanised steel all-thread
Conbextra EP10 pull-out result (10 mm anchor, 13 mm hole, 100 mm embedment)3 days cure; average load 50.1 kN; failure mode steel
Conbextra EP65 Plus pull-out result (12 mm anchor, 18 mm hole, 100 mm embedment, 24 hours cure)Average load 68.8 kN; failure mode steel/concrete
Conbextra EP65 Plus pull-out result (24 mm anchor, 35 mm hole, 200 mm embedment, 3 days cure)Average load 341.1 kN; failure mode steel/concrete
Recommended grout storage temperatureTypically above 10 °C and below 30 °C; ideal 23 °C
Additional mixing time after hardener addition3 minutes

Frequently asked questions

What is this application guide for?

It provides guidance for typical use of Conbextra EP10 and Conbextra EP65 Plus as bonded anchors for vertical anchoring applications.

How long should the concrete cure before anchoring?

A minimum of 28 days (4 weeks) curing should be allowed unless special concrete mixes are being used.

How should the anchor holes be prepared?

They should be percussion drilled vertically into the concrete, then dust and foreign matter blown out with oil-free, dry compressed air and brushing.

How deep should the mixed epoxy be poured into the hole?

The mixed Conbextra EP65 Plus or Conbextra EP10 should be poured to approximately 2/3 the depth of the hole.