The F-400 Series In-Line Flowmeter is an easily installed flowmeter. Please read this instruction manual before installing your flowmeter.
This instruction manual covers the Blue-White F-400 Series in-line variable-area flowmeter. It explains that the meter is designed for easy installation, must be mounted in a vertical plane for accuracy, and that plastic tubing inserted in the flowmeter for shipping protection must be removed before installing.
The document includes installation guidelines, application notes stating the meters are tested and calibrated for water only, maintenance instructions with an exploded view and parts list, meter specifications, a temperature vs. pressure chart, and Blue-White's limited warranty terms with in-warranty repair procedures.
| Accuracy | ± 5% of full scale reading |
|---|---|
| Height | 8.1875" (208.0mm) |
| Width | 1.25" (31.75mm) |
| Scale | Permanent dual scale silkscreen |
| Max pressure / max temperature | See Temperature vs. Pressure chart |
| Meter body material | Acrylic (polysulfone fittings) |
| Float material | #316 Stainless Steel |
| O-ring material | Viton |
It must be installed in a vertical plane to ensure accuracy; misalignment may damage the flowmeter and cause the o-ring seals to leak.
Use only PTFE tape on the threaded adapters, since pipe dope and glue will damage the polysulfone meter body and fittings.
Refer to the Exploded View drawing when reassembling; the tapered tube may be cleaned with a soft bottle brush using a mild soap and water solution.
Variable Area and Digital Flow meters are warranted for 1 year from date of purchase, with proof of purchase required.