The GP-1000 is a portable gas detector for continuous monitoring of combustible gas leaks in hazardous areas.
The Riken Keiki GP-1000 is a portable combustible gas detector designed for continuous monitoring of combustible gas leaks in hazardous locations. Its detection range is 0-100%LEL, and a built-in small pump draws in gas samples; power is supplied only by four LR6 alkaline batteries.
This Japanese user manual covers the product overview, safety notices, components, startup and detection procedures, display and user modes, gas and fault alarm actions, maintenance, storage and disposal, troubleshooting, and specifications. It also lists explosion-proof ratings and certification numbers. This manual is written in Japanese.
| Model | GP-1000 |
|---|---|
| Detection target | Combustible gas (%LEL) |
| Detection range | 0-100%LEL |
| Explosion-proof rating | Ex ia IIC T4 Ga |
| Ambient temperature range | -20 to +50°C |
| Power supply | Four LR6 alkaline batteries (Toshiba) |
| Certification numbers | IECEx DEK 13.0090; ATEX DEKRA 13ATEX0227 |
The detection range is 0-100%LEL.
It uses four LR6 alkaline batteries manufactured by Toshiba.
No. Batteries must be replaced in a non-hazardous location.
The explosion-proof rating is Ex ia IIC T4 Ga.