White-Rodgers BP150/BP150C/BP125C/1E65-151 Line Voltage Thermostat Installation Instructions & User Guide

This document describes the installation instructions and user guide for the White-Rodgers™ thermostat.


White-Rodgers BP150/BP150C/BP125C/1E65-151 Line Voltage Thermostat Installation Instructions & User Guide - cover page
Brand
White Rodgers
Category
Heater
Document type
User Manual
Language
English
Pages
51
File format
PDF
File size
10.8 MB
Published
10 November, 2023
Updated
10 November, 2023
MD5 checksum
B0F441AA080759689CC7855012A4A9FE

About this manual

The White-Rodgers BP150, BP150C, BP125C and 1E65-151 are line voltage programmable thermostats for electric heating units such as electric baseboards, convectors and aeroconvectors. They are designed for resistive loads from 1.25 A to 12.5 A at 120/240 VAC and are not compatible with central heating systems.

The document explains where to mount the thermostat, how to connect two- or four-wire installations, and how to use Manual, Automatic and Preprogrammed modes. It also covers clock and day adjustment, Celsius/Fahrenheit display, set point limits and technical specifications.

What's inside

  • Description
  • Installation
  • Selection of the thermostat location
  • Thermostat mounting and connection
  • Operation
  • Adjustment of the hour and the day
  • Ambient temperature
  • Display in either degrees Celsius / Fahrenheit
  • Technical Specifications

Specifications

Supply voltage120/208/240 VAC, 50/60 Hz
Minimum electrical current with a resistive load1.25 A (150 W @ 120 V; 260 W @ 208 V; 300 W @ 240 V)
Maximum electrical current with a resistive load12.5 A (1500 W @ 120 V; 2600 W @ 208 V; 3000 W @ 240 V)
Temperature display range3°C to 40°C (37°F to 99.5°F)
Temperature display resolution0.5°C (0.5°F)
Temperature set point range3°C to 30°C (37°F to 86°F)
Temperature set point increments0.5°C (1°F)
Storage temperature-40°C to 50°C (-104°F to 122°F)

Frequently asked questions

What current range does the thermostat support with a resistive load?

It supports a resistive load from 1.25 A to 12.5 A at 120/240 VAC.

Where should the thermostat be mounted?

It should be mounted to a connection box on a wall facing the heating unit, about 1.5 m (5 feet) above the floor.

What are the three main operating modes?

The modes are Manual, Automatic and Preprogrammed.

What is the temperature set point range?

The set point range is 3°C to 30°C (37°F to 86°F).