This is a user manual for Blue Universal Thermostat with Automatic Heat/Cool Changeover Option Model Programming Choices 1F95-0671
The White-Rodgers 1F95-0671 is a universal thermostat with automatic heat/cool changeover. The document provides installation and operating instructions, including mounting, battery location, wiring diagrams, installer configuration, thermostat quick reference, programming, and troubleshooting.
It lists applications for heat pump systems with or without auxiliary or emergency heat, systems with up to 4 stages heat and 2 stages cool, heat-only and cool-only systems, gas or oil heat, electric furnace, hydronic zone heat, wired remote temperature sensor, and dual fuel. Specifications include terminal load, setpoint range, differential, operating ambient and humidity, and dimensions.
| Battery power | mV to 30 VAC, NEC Class II, 50/60 Hz or DC |
|---|---|
| Input hardwire | 20 to 30 VAC |
| Terminal load | 1.5A per terminal, 2.5A maximum all terminals combined |
| Setpoint range | 45 to 99°F (7 to 32°C) |
| Differential (single stage) | Heat 0.6°F; Cool 1.2°F |
| Operating ambient | 32°F to +105°F (0 to +41°C) |
| Operating humidity | 90% non-condensing max. |
| Dimensions | 4.2"H x 6.4"W x 1.7"D |
It supports systems with up to 4 stages of heat and 2 stages of cool.
It uses two AA alkaline batteries, which are included with a battery tag.
The setpoint range is 45 to 99°F (7 to 32°C).
Remove the battery tag to engage the batteries.