The E-941DA series of electromagnetic locks is the ideal way to secure double doors against unauthorized entry. When power is applied to the electromagnetic locks, it creates an extremely strong magnetic field. The electromagnets are strongly attracted to the steel armature plates which are mounted on the protected doors. Once the electromagnets are deactivated, the secured doors will open and close normally without any residual magnetism.
The SECO-LARM E-941DA Series consists of double-door electromagnetic locks that secure double doors against unauthorized entry. When power is applied, the electromagnets attract the steel armature plates mounted on the protected doors; when deactivated, the doors open and close normally without residual magnetism.
The manual covers features, parts list, specifications, overview, installation, installation notes, wiring diagram, maximum wiring distance, troubleshooting, and warranty. It lists 600-lb and 1,200-lb models with 12/24 VDC selectable voltage, and notes that E-941DA-1K2P and E-941DA-600PQ models also include dual-color status LEDs and bond sensors.
| Operating voltage | 12 or 24 VDC ±10% |
|---|---|
| Current draw at 12 VDC | 500mA per door (1A total) |
| Current draw at 24 VDC | 250mA per door (500mA total) |
| Coil resistance | 48 ±10% per coil |
| Bond sensor relay | 3A@12VDC |
| Operating temperature | 14°~131°F (-10°~55°C) |
| Weight, 600-lb model | 9 lbs (4 kg) |
| Weight, 1,200-lb model | 21 lbs (10 kg) |
It supports 12 or 24 VDC ±10%, with voltage selection jumpers on each electromagnet.
Green means the door is closed and locked, red means the door is not closed and/or locked, and off means the door is in use or there is no power.
500mA at 12VDC per door, for a total of 1A.
No; once the electromagnets are deactivated, the doors open and close normally without residual magnetism.