About this manual

The ENFORCER Surface-Mount Wave-to-Open Sensor with Manual Override Button is a full-featured exit plate that uses IR technology to allow egress from a protected area or activate a device with the simple wave of a hand. Since no touch is required, this sensor is suitable for use in hospitals, clinics, labs, cleanrooms, schools, factories, or offices. A manual override allows for operation if the sensor is disabled.

The manual provides detailed instructions on mounting and wiring the device, including a wiring diagram and steps for adjusting the sensor range and trigger time. It also covers care and cleaning procedures to ensure reliability and a long operating life.

What's inside

  • Features
  • Parts List
  • Specifications
  • Mounting
  • Wiring Diagram
  • Adjusting Sensor Range
  • Changing LED Color
  • Care and Cleaning

Specifications

Power12~24 VDC
Relay typeSPDT dry contact, 1A@24VDC
Response time10ms
Range19/16 "~6" (4~15 cm)
IP ratingIP54
Operating temperature-20°~55° C

Frequently asked questions

What is the adjustable sensor range?

The sensor range can be adjusted from 19/16 "~6" (4~15 cm).

What is the trigger time adjustment range?

The trigger time can be adjusted from 0.5~30 seconds or toggle.

What is the warranty period?

The product is warranted against defects in material and workmanship for one (1) year from the date of sale.