Sungrow Logger1000A/Logger1000B Data Logger User Manual

The Logger1000A/Logger1000B Data Logger User Manual introduces the features, specifications, installation, operation and maintenance of the Logger1000A/Logger1000B data logger.


Sungrow Logger1000A/Logger1000B Data Logger User Manual - cover page
Brand
Sungrow
Category
Monitoring Equipment
Document type
User Manual
Language
Chinese
Pages
83
File format
PDF
File size
8.3 MB
Published
08 November, 2023
Updated
08 November, 2023
MD5 checksum
7A07911303FFA4C09A016FEA318F3117

About this manual

Sungrow Logger1000A and Logger1000B are data collection, power control and protocol conversion devices for photovoltaic plant equipment such as inverters. This manual covers product description, installation, electrical connection, commissioning, Web interface operation, grid dispatch functions, routine maintenance and appendix information.

Logger1000A is the 4G version and Logger1000B is the non-4G version. The devices support RS485, Ethernet and WiFi communication, multiple environmental sensors, meters, weather stations and inverters, batch parameter configuration and software upgrades, remote desktop, grid control commands and power factor control, and local real-time monitoring without a network. This manual is written in Chinese.

What's inside

  • Product description
  • Installation process
  • Unpacking and storage
  • Mechanical installation
  • Electrical connection
  • Commissioning
  • Web interface
  • Grid dispatch function
  • Routine maintenance
  • Appendix

Specifications

Model variantsLogger1000A (4G version), Logger1000B (non-4G version)
Power inputDC24V
Communication interfacesRS485, Ethernet, WiFi
DC/AC cable recommended cross-section1 mm² to 1.5 mm²
Grounding cable recommended cross-section1 mm² to 1.5 mm²
RS485 dry-contact cable requirementOutdoor UV-resistant shielded twisted pair, 0.75-1.5 mm², maximum distance less than 1000 m
AI dry-contact cable requirementRecommended 0.75 mm², maximum distance 10 m
DI dry-contact cable requirementRecommended 0.75 mm², maximum distance 10 m
Ethernet cable requirementCategory 5e or above, communication distance less than 100 m
PLC cable requirement4-10 mm², maximum distance 1000 m, withstand voltage to ground greater than 1000 V

Frequently asked questions

Which Logger1000 models does this manual cover?

It covers Logger1000A (4G version) and Logger1000B (non-4G version).

What communication methods does Logger1000 support?

It supports RS485, Ethernet and WiFi communication.

What power input does Logger1000 support?

Logger1000 supports DC24V power input.

Does Logger1000 require an app for Web access?

No, it has an embedded Web interface that supports mobile access without downloading an app.

Download PDF (8.3 MB)

More Sungrow Manuals