Deye SUN-K-G Series Grid-Connected PV String Inverter User Manual

This manual describes the features and functions of the SUN-K-G series of photovoltaic inverters.


Deye SUN-K-G Series Grid-Connected PV String Inverter User Manual - cover page
Brand
Deye
Category
string inverters
Document type
User Manual
Language
English
Pages
79
File format
PDF
File size
6.7 MB
Published
07 November, 2023
Updated
07 November, 2023
MD5 checksum
AF5DB3641ABF7B70C77E77CB5AB69BEC

About this manual

This user manual for the Deye SUN-K-G series covers a grid-connected PV string inverter that converts solar panel DC power into AC power which can be fed directly to the grid. It presents the inverter's appearance, the parts supplied in the package, safety signs and safety instructions, and the operation interface with its buttons, LCD display and status indicators.

The manual then explains installation site selection, the mounting bracket and inverter installation, DC input and AC connection, the ground line connection, startup and shutdown, and the zero-export function via an energy meter. It closes with general operation, repair and maintenance, error information and error codes, and specification notes. The manual applies to several models in the series and states that the latest version can be obtained via [email protected].

What's inside

  • Appearance Introduction
  • Parts list
  • Safety instructions
  • Operation Interface
  • Product installation
  • Electrical Connection
  • Startup and Shutdown
  • Zero-export function via energy meter
  • Repair and Maintenance
  • Error information and processing

Specifications

Product typeGrid-tied PV string inverter
TopologyNon-isolated
ConfigurationThree phase string inverter
Panel buttonsFour: Up, Down, ESC, Enter
Included connectorsDC+/DC- plug connectors with metal terminal, N pairs

Frequently asked questions

What is included in the inverter package?

The package includes the inverter, a wall mounting bracket, mounting stainless steel screws, a wrench, stainless steel anti-collision bolts, DC+/DC- plug connectors with metal terminals, a user manual, and optionally a datalogger, meter and sensor clamp.

What should I do if an error code appears and resetting does not solve the problem?

Contact the distributor and provide the inverter serial number, the distributor/dealer, the installation date, a description of the problem including the LCD error code and LED status, and your contact details.

How can I get the latest version of the manual?

The manual states that the latest manual can be acquired via [email protected].