This document describes the installation, operation and maintenance of photovoltaic grid-connected inverters.
This manual covers Deye SUN-3K-G03, SUN-4K-G03, SUN-5K-G03, SUN-6K-G03, SUN-7K-G03, SUN-8K-G03, and SUN-10K-G03 photovoltaic grid-connected string inverters. It describes safety warnings, operating interface, installation, electrical connections, startup and shutdown, zero export function, general operation, repair and maintenance, error codes, and specifications.
The document includes installation requirements such as ventilation, mounting angle, spacing between units, and electrical safety precautions. It also explains status indicators, LCD information, parameter configuration, and troubleshooting guidance for the supported inverter models. This manual is written in Portuguese.
| Maximum installation tilt | 15° |
|---|---|
| Minimum spacing between inverters | 500 mm |
| Discharge wait time after shutdown | 5 minutes |
| Local operating temperature can exceed | 60 °C |
| Local operating temperature can exceed | 80 °C |
| Shelter recommended when ambient temperature exceeds | 100 °F / 40 °C |
The manual covers SUN-3K-G03, SUN-4K-G03, SUN-5K-G03, SUN-6K-G03, SUN-7K-G03, SUN-8K-G03, and SUN-10K-G03.
Wait at least 5 minutes for the inverter to discharge remaining electricity.
The inverter should be installed vertically with a maximum tilt of 15°.
At least 500 mm of space should be left between each inverter.