This document is the Chinese user manual of the R series photovoltaic grid-connected inverter.
This user manual covers the Deye SUN-3.6K-SG01/03LP1-EU and SUN-5K-SG01/03LP1-EU hybrid inverters. It starts with safety introductions and a product overview that identifies the parts of the unit, including the LCD display, function buttons, battery input connectors, RS485 and CAN ports, DRMs port, parallel port, generator input, load and grid terminals, DC switch, PV inputs with two MPPT and the WiFi interface. The manual then describes product features such as pure sine wave single-phase output, self-consumption and feed-in to the grid, programmable supply priority, configurable charging current/voltage and AC/Solar/Generator charger priority, overload, over temperature and short circuit protection, WiFi monitoring and parallel operation on-grid and off-grid.
The installation chapters give the parts list, mounting instructions, battery connection, AC input/output connection, PV connection, CT connection, mandatory earth connection, WiFi connection and single-phase and three-phase parallel wiring diagrams. Later chapters explain power ON/OFF, the operation and display panel, the LCD display icons and setup menus, fault information and processing, limitation of ability, and a datasheet with efficiency, protection, certification, general data and dimensions.
| Output frequency and voltage | 50/60Hz; 220/230/240Vac (single phase) |
|---|---|
| Max continuous AC passthrough | 35 A |
| Power factor | 0.8 leading to 0.8 lagging |
| Max efficiency | 97.60% |
| Euro efficiency | 96.50% |
| MPPT efficiency | 99.90% |
| Operating temperature range | -25~60 °C, derating above 45 °C |
| Noise | <30 dB |
| Weight | 20.5 kg |
| Dimensions (W x H x D) | 580 x 330 x 208 mm |
| Protection degree | IP65 |
| Communication with BMS | RS485; CAN |
| Warranty | 5 years |
| Grid regulation | VDE 0126, AS4777, NRS2017, G98, G99, IEC61683, IEC 62116, IEC 61727 |
It covers the SUN-3.6K-SG01/03LP1-EU and SUN-5K-SG01/03LP1-EU hybrid inverters.
Yes. The manual states the hybrid inverter is designed for outdoor use with IP65 protection, but it should be kept out of direct sunlight, rain and snow.
The operating temperature range is -25 to 60 °C, with derating above 45 °C.
Only qualified personnel can install this device with battery.