SMG2000 series digital dual-clamp phase voltmeter measures AC current, leakage current, AC voltage, inductive, capacitive circuit discrimination, three-phase voltage phase sequence measurement.
The SMG2000 series digital dual-clamp phase volt-ampere meter is a multifunction instrument for field testing. It can measure AC voltage and AC current without opening the circuit, measure phase between two voltages, two currents, or voltage and current, and indirectly obtain power factor and power.
The manual also describes phase sequence identification, transformer connection group identification, inductive/capacitive circuit identification, secondary circuit and busbar protection testing, and checks of electric meter wiring. It includes safety requirements, electrical symbols, technical parameters, instrument structure, operating methods, battery replacement, precautions, packing list, and test wiring reference diagrams. This manual is written in Chinese.
| Power supply | DC 9 V alkaline dry battery (1.5 V LR6 x 6) |
|---|---|
| Operating current with backlight on | Maximum about 35 mA; battery continuous work about 15 hours |
| Operating current with backlight off | About 5 mA; battery continuous work about 100 hours |
| Display | LCD with white backlight |
| LCD size | 70 mm x 62 mm; display area 64 mm x 54 mm |
| Instrument dimensions | 196 mm x 92 mm x 54 mm |
| Sampling rate | About 3 times per second |
| AC voltage range | 0-20 V / 200 V / 500 V |
| AC current range | 0-200 mA / 2 A / 20 A |
| Phase range | 0-360 degrees |
| Data hold | Press HOLD to hold data; DH symbol displays |
| Auto power off | About 15 minutes after power on |
| Low battery indication | Low battery symbol displays when battery voltage is below 7.8-8 V |
| Weight | Host about 1140 g with battery; clamp about 170 g x 2; test leads about 250 g |
| Test lead length | 1.5 m |
| Current clamp lead length | 2 m |
| Operating temperature and humidity | -10 to 40 C; below 80% Rh |
| Storage temperature and humidity | -10 to 60 C; below 70% Rh |
| Input impedance for voltage ranges | 1 Mohm |
| Input impedance for U1-U2 phase voltage | 40 kohm |
| Withstand voltage | 1000 V/50 Hz between circuit and housing for 1 minute; 500 V/50 Hz between two voltage inputs for 1 minute |
| Insulation resistance | At least 10 Mohm |
| Structure | Double insulation |
| Voltage basic error | 20 V: 0.01 V; 200 V: 0.1 V; 500 V: 1 V; +/- (0.5% of range) |
| Current basic error | 200 mA: 0.1 mA; 2 A: 1 mA; 20 A: 10 mA; +/- (0.5% of range) |
| Phase basic error | 0-360 degrees, 1 degree resolution, +/- 1 degree |
It uses a DC 9 V alkaline dry battery (1.5 V LR6 x 6).
It turns off automatically about 15 minutes after being switched on.
No, it cannot be used to test voltages higher than 500 V.
It should be preheated for 3 to 5 minutes before measurement to ensure accuracy.