LCU-1 Liquid Control Unit User Manual Congratulations on the purchase of your new ANTARI LCU-1 Liquid Control Unit.
The Antari LCU-1 Liquid Control Unit user manual provides setup, operation, DMX connection, and maintenance instructions for the unit. It also covers unpacking and inspection, remote and DMX control references, and troubleshooting steps for low output or no output.
Safety cautions address electric shock, burns, and explosion hazards, including ventilation clearance and keeping flammable materials away from the unit. Maintenance guidance recommends cleaning with an 80% distilled water and 20% white vinegar solution after every 40 hours of continuous operation.
| Maximum pump pressure | 7 BAR |
|---|---|
| Maximum fog output | 20,000 cubic feet/minute |
| Ventilation clearance | At least 20 cm |
| Flammable materials distance | At least 50 cm |
| Cleaning solution | 80% distilled water / 20% white vinegar |
| DMX connector | 3-pin or 5-pin XLR |
| Liquid tube | 6 mm PU tube |
A cleaning solution of 80% distilled water and 20% white vinegar.
After every 40 hours of continuous operation.
No, it is for inside use only.
A 3-prong grounded electrical outlet.