About this manual

Congratulations on becoming a user of the Antari Z series second-generation professional fog machine. This manual is designed to help you use the machine safely and effectively to achieve the best results while extending its service life. Please read this guide carefully before starting operation.

The document covers essential safety precautions, installation steps including mounting and oil filling, controller connections (Z-10 On/Off, Z-40 Timer, Z-50 Wireless), maintenance procedures, and detailed technical specifications for the Z-800II, Z-1000II, and Z-1020 models. This manual is written in Chinese.

What's inside

  • Safety Precautions
  • Package Contents
  • Installation
  • Controller Connection
  • Operation
  • Maintenance
  • Technical Specifications
  • DMX Connection

Specifications

Heating Time (Z-800II)Approx. 2 minutes
Oil Consumption Rate (Z-800II)13 oz/min
Tank Capacity (Z-800II)0.8 Liters (0.21 Gallons)
Output Volume (Z-800II)3,000 ft³/min (85 m³/min)
Oil Consumption Rate (Z-1000II)56 oz/min
Tank Capacity (Z-1000II)1.7 Liters (0.45 Gallons)
Output Volume (Z-1000II)12,000 ft³/min (340 m³/min)

Frequently asked questions

Which fog oil is recommended for Antari machines?

Antari recommends using high-quality FLR or FLG water-based fog oils to prevent tube clogging and internal corrosion.

What is the recommended distance for spraying fog?

The machine should be kept at least 50cm away from people and animals during operation due to high temperature.

What are the safety requirements for electrical connection?

The machine must be used indoors only, kept dry, and connected to a grounded outlet matching its voltage specifications.

How should the fog machine be maintained?

After 40 hours of use, clean the nozzle with distilled water and run the machine until the tank is empty to remove residue.