The document introduces a product with the brand name 27, which has multiple features and characteristics.
Congratulations on becoming a user of the Antari Z series second-generation professional fog machine. This manual is designed to help you use the machine safely and effectively to achieve the best results while extending its service life. Please read this guide carefully before starting operation.
The document covers essential safety precautions, installation steps including mounting and oil filling, controller connections (Z-10 On/Off, Z-40 Timer, Z-50 Wireless), maintenance procedures, and detailed technical specifications for the Z-800II, Z-1000II, and Z-1020 models. This manual is written in Chinese.
| Heating Time (Z-800II) | Approx. 2 minutes |
|---|---|
| Oil Consumption Rate (Z-800II) | 13 oz/min |
| Tank Capacity (Z-800II) | 0.8 Liters (0.21 Gallons) |
| Output Volume (Z-800II) | 3,000 ft³/min (85 m³/min) |
| Oil Consumption Rate (Z-1000II) | 56 oz/min |
| Tank Capacity (Z-1000II) | 1.7 Liters (0.45 Gallons) |
| Output Volume (Z-1000II) | 12,000 ft³/min (340 m³/min) |
Antari recommends using high-quality FLR or FLG water-based fog oils to prevent tube clogging and internal corrosion.
The machine should be kept at least 50cm away from people and animals during operation due to high temperature.
The machine must be used indoors only, kept dry, and connected to a grounded outlet matching its voltage specifications.
After 40 hours of use, clean the nozzle with distilled water and run the machine until the tank is empty to remove residue.