Salamandras a gas Línea Infrarojos San-Son® is a gas heater with the following features: 1. Rugged construction for long life 2. High heating efficiency and energy saving 3. Easy to operate and maintain
This is the Spanish quick-operation manual ("Manual de manejo rápido") for San-Son gas infrared salamanders and gratinators in models Colgante, 75 and 140 (ZCOLGANTE / ZAL 75 / ZAL 140). The document describes the product configurations: a hanging salamander with a gas burner, swing system and 5-position rack, and a gratinator with an infrared gas burner and 3 cooking levels. It states that the burners can generate up to 800 °C and that the units are for commercial restaurant use, not domestic use.
The manual covers installation and ventilation, the gas supply valve, required gas pressure and pipe sizing, leak testing with soapy water, the data plate, lighting the pilots and burners, final preparation, the chrome wire grates, cleaning and maintenance, and technical configuration. Contact and service addresses for San-Son in Mexico City, Guadalajara and Cancún are given at the end. This manual is written in Spanish.
| Design gas pressure | 9 to 11 OSI (oz/in²) or 15.5 to 19 in. WC |
|---|---|
| Measured gas pressure | 10.5 oz/in² static, 9 oz/in² in demand |
| Burner output temperature | up to 800 °C |
| Gas connection diameter | 1/2" NPT |
| Supply pipe | 1/2" NPT male, schedule 40 |
| Supported gas types | Natural or LP gas |
| Maximum main line length | no more than 20 ft (6 m) |
| Intended use | Commercial restaurant grade, not domestic |
It must be installed at a design pressure of 9 to 11 OSI (oz/in²) or 15.5 to 19 in. WC; incorrect pressure causes poor operation.
The unit must be connected to a 1/2" NPT gas line; a smaller diameter will cause performance problems.
No; converting it requires changes that must be made by the factory technical service, and the manual says not to attempt the modification.
Open the windows, shut off all flames by closing the main gas valve of the salamander or any other gas or electric equipment present, and immediately call the leak center or your supplier.