Circutor Computer SMART III FAST 12Vdc Reactive Energy Regulator Programming Guide

The Computer SMART III 6 FAST 12Vdc / SMART III 12 FAST 12Vdc regulator measures the power grid cosine and controls capacitor connection and disconnection in order to correct it. It also calculates and displays the main electrical parameters of balanced or unbalanced single-phase and three-phase networks.


Circutor Computer SMART III FAST 12Vdc Reactive Energy Regulator Programming Guide - cover page
Brand
Circutor
Category
Power Management
Document type
Programming Manual
Language
English
Pages
2
File format
PDF
File size
1.4 MB
Published
06 November, 2023
Updated
06 November, 2023
MD5 checksum
D35EE548F9C3F7399BAF1E0544DD8FCB

About this manual

This is a Spanish/English programming and commissioning guide for the Circutor Computer SMART III 6 FAST 12Vdc and SMART III 12 FAST 12Vdc reactive energy regulators. The text states that these regulators measure the power grid cosine and control capacitor connection and disconnection to correct it, and that they calculate and display main electrical parameters in balanced or unbalanced single-phase and three-phase networks.

The guide covers keyboard functions and display indicators, a C/K factor table and calculation example, and configuration screens for password, current transformer ratio, target cos phi, connection and reconnection times, connection type, phase sequence, number of stages, stage program and C/K factor. It also refers to an advanced setup and shows a simulation display for connecting previously indicated steps, with the full manual available from the Circutor website.

What's inside

  • Status of the capacitors
  • Status of the device
  • Keyboard functions
  • Display indicators
  • Calculating the C/K Factor
  • Setup menu
  • Advanced Setup
  • Connection type
  • Phase connection
  • Simulation data

Specifications

Number of relay outputs6, 12 or 14 depending on model
CT primary range1 to 9999
CT secondary values1 or 5
Connection types3U3C, 3U1C, 2U1C
Recommended t.on / t.rec10 / 50
Network typesBalanced or unbalanced single-phase and three-phase
Displayed parametersMain electrical parameters

Frequently asked questions

What does the Computer SMART III FAST 12Vdc regulator do?

It measures the power grid cosine and controls capacitor connection and disconnection to correct it.

How many relay outputs can be configured?

The guide states 6, 12 or 14 outputs according to model.

What are the recommended t.on and t.rec settings?

The recommended values are t.on = 10 and t.rec = 50.

What CT secondary values are possible?

The possible secondary values are 1 or 5.