CIRCUTOR CVM-MINI-LON Power Analyzer User Manual

User manual for the CIRCUTOR CVM-MINI-LON three-phase power analyzer covering setup menus, LonWorks communications, alarm outputs and specifications.


CIRCUTOR CVM-MINI-LON Power Analyzer User Manual - cover page
Brand
Circutor
Category
Analyzers
Document type
User Manual
Language
Spanish
Pages
2
File format
PDF
File size
1.4 MB
Published
07 November, 2026
Updated
07 November, 2026
MD5 checksum
1EBBDCB5D157FC0F5C84017B0ED06A88

About this manual

The CVM-MINI-LON is an instrument that measures, calculates and displays the main electrical parameters in three-phase industrial networks, balanced or unbalanced. Measurement is made in true RMS value through three AC voltage inputs and three AC current inputs (via IN/5A or IN/1A current transformers), and the measured and calculated parameters are shown in the variables table. This document is the user and operation manual for the CVM-MINI-LON, and CIRCUTOR states it can be downloaded from www.circutor.es.

The manual describes the SETUP programming menu, including voltage and current transformer primary and secondary values, two- or four-quadrant measurement, the maximeter, screen display and backlight settings, energy counter reset and THD/d selection, as well as the transistor alarm outputs. It also covers the service button for LonWorks identification, the twisted-pair LonWorks connection at 78 Kbits per second with up to 128 devices and 500 metres per network segment, the technical characteristics, wiring and CIRCUTOR technical service contact details. This manual is written in Spanish.

What's inside

  • Programación (menú SETUP)
  • Transformador de tensión y de corriente
  • Medida en 2 ó 4 cuadrantes
  • Programación del Maxímetro
  • Programación de pantallas y backlight
  • Puesta a cero de contadores de energía
  • Programación THD ó d
  • Salidas de alarma de transistor
  • Identificación Service PIN y LonWorks
  • Comunicaciones

Specifications

Power supply (ac version)230 Vac -15 % / +10 %
Frequency50 - 60 Hz
Operating temperature-10 ºC to +50 ºC
Nominal voltage300 Vac phase-neutral / 520 Vac between phases
Measurement frequency range45 ~ 65 Hz
Nominal currentIN / 5 A or IN / 1 A
ProtectionIP 51 front, IP 31 sides and rear cover
Dimensions85 x 52 x 70 mm (3 pasos)
LonWorks transmission speed78 Kbits per second
Maximum devices per network128 devices
Distance per network segment500 metres
Transistor outputsNPN opto-isolated, 24 V d.c., 50 mA

Frequently asked questions

How do I enter the programming menu?

Press the SETUP key for 5 seconds to enter the SETUP menu.

What communication protocol does the CVM-MINI-LON use?

It connects to a LonWorks network over a twisted-pair connection at 78 Kbits per second, following the LonTalk protocol.

How many devices can a LonWorks segment support?

Up to 128 devices, with a distance of 500 metres per network segment.

Which current transformer secondaries can be programmed?

The secondary ratio can be set to IN/5A or IN/1A.