This is the manual of MEV2000 series variable frequency drive, which introduces the safety information, product introduction, installation and wiring, operation and operation instructions, detailed function introduction and other contents
This manual is for the MEV2000 series general-purpose variable frequency drive from Control Techniques. It provides safety information, product introduction, installation and wiring guidance, operation instructions, parameter settings, fault handling, and maintenance information.
The document also includes model and rating information, installation methods, EMC installation guidance, daily maintenance, and accessory and terminal information for the drive. This manual is written in Chinese.
| Rated power range | 0.37-45 kW |
|---|---|
| Input voltage (low range) | 200-240 V |
| Input voltage (high range) | 380-480 V |
| Altitude derating | 1% per 100 m above 1000 m; 20% at 3000 m |
Check for damage, confirm the nameplate ratings match the order, and contact the company or supplier if there is damage or missing parts.
No. Installing power-factor correction capacitors or surge suppressors on the output can cause faults or damage.
Above 1000 m, the rated output current decreases by 1% for every 100 m; at 3000 m it is 20% lower.
Wait 10 minutes after disconnecting power and make sure the DC bus voltage is below 36 V.