This document is the instruction manual for the GX-8000 portable gas detector. It mainly introduces the product's usage methods, maintenance checks, storage and disposal.
This is the Chinese instruction manual (PT0-098) for the Riken Keiki GX-8000 portable gas detector, a device that draws in air with a built-in pump and detects combustible gases, oxygen, carbon monoxide and hydrogen sulfide in hazardous locations. The manual covers the product overview, safety information including ATEX/IECEx explosion-proof data, standard accessories and part names, and the basic operating procedure.
It then explains startup, detection, the air calibration (zero adjustment) mode, the display/setting modes such as combustible gas range, PEAK, STEL and TWA values, alarm test, pump on/off, ID and logged data, gas and fault alarm behavior, maintenance and gas calibration, storage and disposal, troubleshooting, and the product specifications. This manual is written in Chinese.
| 防爆等级 | Ex ia ⅡC T4 Ga(Ⅱ1G Ex ia ⅡC T4 Ga) |
|---|---|
| 电源 | 锂离子电池单元 BUL-8000(G)/BUL-8000(G1) 或干电池单元 BUD-8000(G)/BUD-8000(G1) |
| IECEx 检定合格编号 | IECExKEM10.0038 |
| ATEX 检定合格编号 | KEMA10ATEX0085 |
| 适用标准 | IEC60079-0:2011、EN60079-0:2012、IEC60079-11:2011、EN60079-11:2012 |
| 手动存储器记录条数 | 最多 256 条(超过上限后从最早的记录开始覆盖) |
Press and hold the POWER key for about 3 seconds or more; the LCD and alarm lamp light up and the buzzer sounds once, followed by the date/time display.
The air calibration mode performs the zero adjustment of the detector.
Up to 256 readings can be recorded; when the limit is reached, the oldest record is overwritten.
The explosion-proof rating is Ex ia ⅡC T4 Ga.