Sinomeasure 80 Series Low-Frequency Radar Level Meter User Manual

This product is a radar level meter that uses a special related demodulation technology to accurately identify the time interval between the transmitted pulse and the received pulse, and then further calculate the distance from the antenna to the measured medium surface. Even in complex working conditions, with the latest microprocessor technology and debugging software, the echo of the material can be accurately analyzed to obtain accurate measurement results.


Sinomeasure 80 Series Low-Frequency Radar Level Meter User Manual - cover page
Brand
Sinomeasure
Category
sensor
Document type
User Manual
Language
Chinese
Pages
42
File format
PDF
File size
3.6 MB
Published
03 November, 2023
Updated
03 November, 2023
MD5 checksum
F2ABF5ABF713A64786064546A9F3F407

About this manual

This Chinese user manual covers the Sinomeasure 80 series low-frequency radar level meters (models 801, 802, 803, 803T, 804 and 805). It explains the microwave pulse measuring principle, the distance and level calculation, and the applications of the 6 GHz series for contactless continuous level measurement of liquids, slurries, granules and bulk solids.

The manual describes the individual model versions and their antennas, then walks through installation (tank shape, mounting position, stilling well, nozzle height), electrical connection and supply, commissioning via display/keys, PC or HART handheld programmer, housing and horn dimensions, technical parameters, maintenance notes, and warranty and after-sales service. Document number U-SIN-RD80-CN2, second edition, July 2021. This manual is written in Chinese.

What's inside

  • Product Overview
  • Measuring Principle
  • Application Introduction
  • Meter Introduction (Models 801–805)
  • Meter Installation
  • Installation Position Guidance
  • Electrical Connection
  • Protection Class IP66/67
  • Meter Commissioning
  • Structural Dimensions

Specifications

Frequency6 GHz
Measuring range (801 / 802)0–20 m
Measuring range (803)0–35 m
Measurement accuracy±10 mm at 5 m range; ±20 mm at 20 m range
Output signal(4–20) mA / HART
Resolution1.6 µA
Supply voltage, two-wire24 VDC
Supply voltage, four-wire(198–242) VAC
Power consumptionmax. 22.5 mA
Protection classIP66/67
Maximum tank pressureMax. 4 MPa
Display resolution1 mm
Process temperature (801)(-40~130) °C
Relative humidity<95%

Frequently asked questions

What is the measuring range of the 801 and 802 radar level meters?

Both the 801 and 802 have a measuring range of 0 to 20 m. The 803 reaches 0 to 35 m.

What output signal and power supply does the meter use?

The output is (4–20) mA with HART, and the meter can be supplied as a two-wire version with 24 VDC or a four-wire version with 24 VDC or 220 VAC.

Can the low-frequency radar level meter be used in explosion-proof areas?

No. The manual states the product must not be used in explosion-proof (hazardous) locations.

How accurate is the measurement?

Accuracy is ±10 mm at a 5 m range and ±20 mm at a 20 m range for the 801 and 802; the 803 is ±15 mm at 20 m and ±20 mm at 35 m.

Download PDF (3.6 MB)