Tonghui TH2837X/TH2898KX Transformer Comprehensive Tester Operation Manual

This is a product manual that introduces the function, characteristic, use method and note of TH2837X/TH2898KX series transformer comprehensive tester produced by Tonghui Electronic Co., Ltd. in Changzhou.


Tonghui TH2837X/TH2898KX Transformer Comprehensive Tester Operation Manual - cover page
Brand
Tonghui
Category
Other Electronics
Document type
User Manual
Language
Chinese
Pages
205
File format
PDF
File size
2.1 MB
Published
03 November, 2023
Updated
03 November, 2023
MD5 checksum
D7C38B5D2965151915BEDB63C623703C

About this manual

This operation manual covers the Tonghui TH2837X/TH2898KX series transformer comprehensive tester. It describes unpacking, power connection, front and rear panels, display areas, and basic operation.

The manual explains LCR measurement functions, transformer single-machine and automatic scan tests, comparator and limit settings, file management, user calibration, and command reference for remote control. This manual is written in Chinese.

What's inside

  • 开箱安装
  • 概述
  • [DISP]菜单键说明
  • [SYSTEM] 菜单键说明和文件管理
  • 执行 LCR测量操作及一些示例
  • 变压器单机测试
  • 变压器自动扫描测试
  • 命令参考

Specifications

Test frequency range20Hz—200kHz / 20Hz-500kHz
Basic measurement accuracy0.05% (LCRZ)
DCR display range0.00001 Ω-999.999 MΩ
Measurement speed75 readings/second fast
Dimensions430mm×185mm×473mm
Power consumptionmaximum 80VA

Frequently asked questions

What is the test frequency range of the TH2837X/TH2898KX series?

The test frequency range is 20Hz—200kHz or 20Hz-500kHz with 0.01% accuracy depending on the model.

What are the dimensions and weight of the instrument?

The instrument measures 430mm×185mm×473mm and weighs about 13 kg.

What is the maximum power consumption?

Maximum power consumption is 80VA.