VP3000 Series 3-Port Solenoid Valve Instruction Manual

VP3000 series solenoid valve operating instructions, including safety precautions, design considerations, selection, installation, piping, wiring, lubrication, air supply, operating environment, maintenance and repair, other precautions, specifications, coil type, flow characteristics and quality, JIS marking, solenoid valve model indication method, external pilot valve ASSY model indication method, fault and handling method, etc.


VP3000 Series 3-Port Solenoid Valve Instruction Manual - cover page
Category
Other
Document type
User Manual
Language
Chinese
Pages
12
File format
PDF
File size
363 KB
Published
03 November, 2023
Updated
03 November, 2023
MD5 checksum
028953D25F61F1199E466818C848BDB7

About this manual

This instruction manual covers the VP3000 Series 3-port solenoid valve and is identified by document number VP3145*-OMI0002. It begins with safety precautions and design and selection notes.

The manual then covers installation, piping, wiring, lubrication, air supply, operating environment, and maintenance. It also includes specifications, coil types, flow characteristics, JIS symbols, model numbering, and troubleshooting. This manual is written in Chinese.

What's inside

  • Safety Precautions
  • Installation
  • Piping
  • Wiring
  • Lubrication
  • Air Source
  • Operating Environment
  • Maintenance
  • Specifications
  • Troubleshooting

Specifications

DC coil leakage voltage5% or less of rated voltage
AC coil leakage voltage15% or less of rated voltage
Minimum ON/OFF time for instantaneous energization0.1 s or more
Low-temperature operating limit0°C
Recommended lubricating oilTurbine oil No. 1 (additive-free) ISO VG32
Air filter filtration5 μm or less
Terminal screw tightening torque0.5 N·m ±15%
Wire outer diameter6–12 mm

Frequently asked questions

What is the representative model of this solenoid valve?

The representative model is the VP3000 Series.

What oil is required for lubrication?

The manual specifies turbine oil No. 1 (additive-free) ISO VG32 and says lubrication should be continued.

What is the minimum ON/OFF time for instantaneous energization?

The ON and OFF times must each be at least 0.1 s.

What filtration rating is recommended for the air filter?

An air filter with a filtration rating of 5 μm or less should be installed upstream of the solenoid valve.