Motor installation, including motor wiring, grounding, and providing motor wiring diagrams and motor nameplate information
This guide provides electrical installation instructions for Pentair pool pump motors, including wiring, grounding, and bonding requirements for swimming pool, spa, and hot tub installations.
It also includes safety warnings, conductor and bonding specifications, and motor-specific diagrams showing ground screws, bonding lugs, and shaft flats.
| Bonding conductor (US) | Not smaller than 8 AWG solid copper |
|---|---|
| Bonding conductor (Canada) | 6 AWG or larger solid copper |
| Bonding distance | Within 5 feet (1.52 meters) of inside walls |
| Servicing wait time | At least 60 seconds |
| Liquid-tight receptacle | 1/2 inch NPT |
| Motor shaft flats | For 1/2 inch wrench or 1/4 inch Allen wrench |
Be sure all electrical connections are tight and all electrical and wiring compartment covers are properly installed.
Use a solid copper bonding conductor not smaller than 8 AWG, or 6 AWG or larger in Canada.
Bond metal parts within 5 feet (1.52 meters) of the inside walls.
Wait at least sixty (60) seconds before servicing.