Yamaha RCX240 / RCX240S 4-Axis Robot Controller User's Manual

This manual describes the safe use methods, operating methods, and maintenance methods of the Yamaha RCX240 controller. It is suitable for users and maintenance personnel of this product.


Yamaha RCX240 / RCX240S 4-Axis Robot Controller User's Manual - cover page
Brand
Yamaha
Category
Robot
Document type
User Manual
Language
English
Pages
323
File format
PDF
File size
6 MB
Published
01 November, 2023
Updated
01 November, 2023
MD5 checksum
33BA4CBB7A810DADC62BF93541D7CD35

About this manual

This is the user's manual for the Yamaha RCX240 and RCX240S 4-axis robot controllers (document EUR6137202, Ver. 2.02). It begins with safety instructions, warning labels and precautions for each stage of use, then describes the system configuration, optional devices such as the programming box, expansion I/O board and regenerative unit, and the basic sequence from installation to operation.

The main chapters cover installation and power wiring, the parallel I/O interface, the SAFETY I/O interface, the RS-232C interface, controller system settings and parameters, the two-robot setting, periodic inspection, specifications, and troubleshooting with error message lists. The manual also explains procedures such as emergency stop reset, absolute battery connection and replacement, and parameter initialization.

What's inside

  • Safety Instructions
  • System overview
  • Installation
  • Parallel I/O interface
  • SAFETY I/O interface
  • RS-232C interface
  • Controller system settings
  • Two-robot setting
  • Periodic inspection
  • Specifications

Specifications

Main power supply voltage (motor power)200 to 230V AC
Control power supply voltage200 to 230V AC
Main power wire cross-section2.0sq or more
Control power wire cross-section1.25sq or more
GroundingClass D grounding (100 ohms or less)
Terminal tightening torque1.4 Nm

Frequently asked questions

What power supply voltage does the RCX240 controller use?

The manual specifies 200 to 230V for both the main motor power supply (L/N) and the control power supply (L1/N1), and instructs users to check that the supply voltage matches the controller's power specifications before connecting the power cable.

Does the RCX240 controller need to be grounded?

Yes. To prevent electrical shocks or faulty operation caused by noise, the earth terminal (protective conductor) must be properly grounded, with Class D grounding of 100 ohms or less.

What wire cross-section is required for the AC power wiring?

The main power supply (L/N) requires a wire cross-section of 2.0sq or more, and the control power supply (L1/N1) requires 1.25sq or more; 1sq indicates 1 square millimeter of stranded wire.

Is it safe to touch the AC IN terminals while the controller is powered?

No. The manual warns that to prevent electrical shocks, the AC IN terminals must never be touched when power is supplied to the robot controller.