Instructions for installation, maintenance and other information
This two-page guide walks through installing a toilet using 5/16" T-bolts, a wax seal or gasket, and floor or wall bolts. It covers floor-outlet and wall-outlet models, setting the T-bolts, leveling and tightening the tank bolts, connecting the water supply, and checking for leaks.
The guide also lists important safety and pressure information: no oils or lubricants should be used on the system, tanks of different sizes need different minimum supply pressures, and the gap between the actuator and the plunger arm must be set so the toilet flushes properly.
| T-bolt size | 5/16" |
|---|---|
| Minimum supply pressure, 1 gallon (3.8 L) tank | 35 psi (241 kPa) |
| Minimum supply pressure, 1.4 gallon (5.3 L) or 1.6 gallon (6.0 L) tank | 20 psi (138 kPa) |
| Actuator-to-plunger-arm gap | 1/16" (2 mm) – 1/8" (3 mm) |
A 1 gallon (3.8 L) tank requires at least 35 psi (241 kPa); 1.4 gallon (5.3 L) and 1.6 gallon (6.0 L) tanks require at least 20 psi (138 kPa).
No. The guide states that no oils or lubricants should be used on the system.
Loosen the setscrew and turn the actuator; turning clockwise increases the gap. Then retighten the setscrew.
Check for a 1/16" (2 mm) to 1/8" (3 mm) gap between the actuator and the plunger arm.