This manual introduces the installation methods of Hi-drive products.
Parker Hannifin's Hi-drive quick installation guide covers the HID2, HID5, HID8, HID16 and HID25 converter models. It provides safety warnings, hardware specifications, installation, identification, assembly, dimensions and environmental characteristics.
The guide states that it refers to the standard product and does not replace the complete operator's manual, which is available on the supplied CD-ROM. It also lists EMC conformity and safety standards.
| Available models | HID2, HID5, HID8, HID16, HID25 |
|---|---|
| Three-phase rated voltage | 200 V~ -10% to 480 V~ +10% |
| Single-phase rated voltage | 200 V~ -10% to 277 V~ +10% |
| DC supply voltage | 245 to 744 V= |
| AC supply frequency | 50 to 60 Hz ±5% |
| Continuative output current | 2, 5, 8, 16, 25 Arms (by model) |
| Peak output current (2 s) | 4, 10, 16, 32, 50 Arms (by model) |
| Maximum output frequency | 0 to 500 Hz |
| Control DC power supply | 24 V= (0% to +10%) |
| Control power input | 30 W |
| Parking brake power supply | 24 V= ±10% |
| Parking brake maximum current | 2 A= |
| Storage temperature | -20°C to +65°C |
| Operating temperature | 0°C to +45°C |
| Room humidity | Less than 85% |
| Maximum installation altitude | 1000 m asl |
| Degree of protection | IP20 |
| Degree of pollution | 2 or below |
| Frame width | 87 mm (HID2/5/8), 122 mm (HID16/25) |
It covers five models: HID2, HID5, HID8, HID16 and HID25.
No. It refers to the standard product and does not replace the more complete operator's manual available on the supplied CD-ROM.
Leave at least 100 mm of free space above, below and in front of the drive.
Yes. Leakage current exceeds 3.5 mA, so all housing and motor must be permanently grounded using a copper conductor with at least 10 mm2 cross section.