This document is a headset maintenance manual, which lists the headset's components and models in detail and provides instructions for use
This service manual provides detailed instructions for repairing and maintaining AKG K612 and K712 headsets. It includes a parts list with component descriptions, part numbers, and quantities. Repair steps cover removing cushions, accessing internal components, replacing capsules, and swapping rubber loops. Specific guidance is given for disassembling and reassembling parts, including torque and phasing requirements for capsule replacement.
The manual is bilingual, with instructions in both English and German, and includes diagrams and part numbering for clarity. This manual is written in German.
Turn the cushions counter-clockwise to release the bayonet lock.
Unsolder all leads, loosen screws 15, remove the cardan swivel with capsule. After inserting the new capsule, tighten screws 15 with moderate force only and ensure correct phasing.
Break out cover 3 by inserting a screwdriver into the notch below the CE sign, then undo locking knob 7 by depressing its latches while pressing the knob out.