User manual for the AKG C451 B condenser microphone, covering safety, connection, application, cleaning, and technical specifications.
This manual provides instructions for the AKG C451 B reference condenser vocal microphone. It covers safety precautions, environmental considerations, and a description of the included items and optional accessories. The guide details the microphone's unique features, such as its robust metal construction and low self-noise, and explains its modular design which avoids the mechanical disadvantages of previous versions. This manual is written in German.
| Polar pattern | Niere |
|---|---|
| Frequency response | 20 bis 20.000 Hz |
| Output impedance | < 200 Ohm |
| Recommended load impedance | > 1000 Ohm |
| Maximum SPL (0 dB attenuation) | 135 dB SPL |
| Dynamic range | 117 dB max. |
| Phantom power | 9 - 52 Volt |
| Connector | 3-pol. XLR-Stecker |
| Dimensions | 19 mm Ø x 160 mm |
| Weight (net) | 125 g |
The frequency response ranges from 20 Hz to 20,000 Hz with a deviation of ± 1.5 dB from the nominal curve.
You must switch on an optional phantom power device between the microphone and the mixer input.
The package includes the C451 B microphone, a stand adapter (SA60), a windscreen (W90), and a Soundtool Case (small).