This manual mainly introduces the characteristics, usage methods, installation methods and maintenance methods of 53NQHE018-072 series air conditioner products
This manual covers product information, service, and installation for a medium static pressure ducted split air conditioner. It includes nomenclature, physical and electrical data, capacity tables, and fan performance.
The service and installation section covers precautions, indoor and outdoor unit installation, refrigerant and drain piping, new air duct installation, drain pump and motor maintenance, wiring, and operation testing. This manual is written in Spanish.
| Cooling capacity (18K model) | 5270 W |
|---|---|
| Heating capacity (18K model) | 5570 W |
| EER (18K cooling) | 2.40 W/W |
| COP (18K heating) | 3.28 W/W |
| Indoor airflow high/medium/low (18K) | 950/770/670 m3/h |
| External static pressure (18K high) | 70 Pa |
| Indoor noise high/medium/low (18K) | 40/37/35 dB(A) |
| Indoor unit dimensions (18K) | 880 x 674 x 210 mm |
| Indoor unit net/gross weight (18K) | 23.7/29.2 kg |
| Refrigerant | R410A |
| Refrigerant charge (18K) | 1.5 kg |
| Design pressure liquid/gas | 4.2/1.5 MPa |
| Maximum pipe length (18K/24K) | 25 m |
| Maximum level difference (18K/24K) | 15 m |
| Outdoor unit dimensions (18K) | 770 x 300 x 555 mm |
| Outdoor unit net/gross weight (18K) | 36.5/38.8 kg |
| Outdoor noise (18K) | 61 dB(A) |
| Controller | KJR-10B/DP(T)-E |
| Operating temperature cooling/heating | 17-32 / 0-30 °C |
The system uses R410A refrigerant.
The specified controller is KJR-10B/DP(T)-E.
Cooling operation is 17-32 °C and heating operation is 0-30 °C.
The maximum pipe length is 25 m.