This is an installation manual for a drawer refrigerator
This document is an installation guide for Gaggenau RB 472 and RB 492 refrigerator-freezers. It describes installation methods, site requirements, electrical and water connections, leveling, anti-tilt measures and cabinet door preparation.
It also lists required accessories and tools, installation space dimensions, climate classes, filled weights and step-by-step installation procedures. This manual is written in Chinese.
| Electrical supply | 220-240 V/50 Hz |
|---|---|
| Fuse rating | 10 A to 16 A |
| Water hose length | 2 m |
| Water pressure | 0.2 MPa to 0.8 MPa |
| Maximum water pipe outer diameter | 10 mm |
| Minimum installation space depth | 610 mm |
| Side wall and top panel thickness | at least 16 mm |
| Baseboard thickness | at least 19 mm |
| Appliance width | 756, 762, 908 or 914 mm |
| Filled weight | about 550 kg (75.6 cm model) or 600 kg (90.3 cm model) |
| Allowed ambient temperature | SN +10 to 32 C; N +16 to 32 C; ST +16 to 38 C; T +16 to 43 C |
It must be connected to 220-240 V/50 Hz AC through a grounded socket with a 10 A to 16 A fuse.
The connection must be between 0.2 MPa and 0.8 MPa; above 0.8 MPa a pressure safety valve is required.
The installation space depth must be at least 610 mm.
The listed climate classes are SN, N, ST and T, with ambient temperature ranges from +10 C to +43 C depending on class.