MPM/MDM transmitter controller product manual, introduces the product overview, safety warnings, performance indicators, appearance structure, electrical connection, key settings, installation, communication instructions, responsibilities and other contents.
MPM/MDM series transmitter controllers from 麦克传感器 are intelligent instruments for pressure, differential pressure and liquid level measurement, display and control. The series includes MPM/MDM484C, MPM/MDM460, MPM460W and MPM/MDM484ZL subseries, with electronic construction, standard signal output and RS485 (Modbus RTU) communication.
The manual covers safety warnings, performance specifications, outline structure, electrical connections, key settings, installation and communication commands. Applications include hydropower, water supply, water treatment, petroleum, chemical and metallurgical industries. This manual is written in Chinese.
| Measurement range (liquid level) | 0 m to 200 mH2O (MPM460W only) |
|---|---|
| Measurement range (pressure) | -100 kPa to 100 MPa |
| Measurement range (differential pressure) | 0 kPa to 3.5 MPa |
| Overload pressure (pressure) | 1.5 times full scale or 110 MPa, whichever is smaller |
| Overload pressure (differential) | Static pressure ≤20 MPa |
| Overload pressure (liquid level) | 1.5 times full scale |
| Power supply | 220 V AC, 110-370 V DC, or 24 V DC |
| Analog output | 4-20 mA, 0-10/20 mA, 0/1-5/10 V DC |
| Digital output | RS485 (Modbus RTU) |
| Ambient temperature | -10 to 60 °C |
| Medium temperature | -10 to 80 °C |
| Storage temperature | -40 to 80 °C (-20 to 80 °C for 460W sensor) |
| Relative humidity | 0% to 80% |
| Vibration | ≤3 g, 0-300 Hz |
| Stability | ≤±0.3%/year |
| Maximum power consumption | ≤3.5 W (≤5 W for 460 series with 5-8 control points) |
| Accuracy | ≤±0.25% FS typical, ≤±0.5% FS maximum |
| Relay load capacity | 240 V/3 A AC or 30 V/3 A DC |
| Contact life | >100,000 operations |
| Main display | 0.56 in (460, 484C) or 0.8 in (484ZL) |
| Sub display | 0.36 in (460, 484ZL) |
| Display range | -1999 to 9999 |
| Sampling speed | 10 times/second |
| Control contacts (460 series) | 1 to 8 points |
| Installation | Vertical, axial (MPM484ZL, MPM484C), submersible (MPM460W) |
| Protection rating | IP65 display housing (MPM460(W), MDM460); IP68 sensor (MPM460W) |
| Pressure interface (gauge) | M20×1.5 external thread |
| Sensing diaphragm | 316L stainless steel |
| Electronic housing | Stainless steel |
| Sealing | Nitrile rubber or all-welded |
It uses an RS485 interface with the Modbus RTU protocol.
The 460 series provides 1 to 8 control points.
Typical accuracy is ≤±0.25% FS and maximum accuracy is ≤±0.5% FS.
It is installed vertically downward as a submersible sensor.