This document describes the use of Sokkia SET 4BII electronic total stations.
This document covers the use of the Sokkia SET 4B II Electronic Total Stations and the Sokkia SDR-33 Electronic Notebook. It explains instrument setup in nine steps, from planning the survey and setting up and leveling the tripod to configuring the total station and determining orientation to a backsight point.
It also describes use of the total station keyboard and SDR33, making angle and distance measurements, precise angle measurement methods, quadrilateral and geophysical line (traverse) surveys, downloading SDR33 jobs, and adjusting a traverse. The instruments are stated to measure angles to 5” (0.00139°) and distances to ± 5 mm + 3 ppm.
| Angle measurement accuracy | 5” (0.00139°) |
|---|---|
| Distance measurement accuracy | ± 5 mm + 3 ppm |
| Default prism constant | -40mm |
The instruments can measure angles to 5” (0.00139°) and distances to ± 5 mm + 3 ppm (5 mm + 3 mm per km).
Press the ENT SHIFT key (bottom right) then the EDM key, select item [3. ppm], then item [2. Temp & Press], and enter the temperature and pressure.
Rotate the telescope about the vertical axis by 360° and then about the horizontal axis by 360°. You should hear a beep at each point.