AC9100A Weighing Indicator Instruction Manual

This manual is the instruction manual for AC 9100A weighing indicator, which introduces the product's features and characteristics, installation and use methods, maintenance methods and other content


AC9100A Weighing Indicator Instruction Manual - cover page
Category
Other products
Document type
User Manual
Language
Chinese
Pages
57
File format
PDF
File size
2.4 MB
Published
30 October, 2023
Updated
30 October, 2023
MD5 checksum
BFD4AAC747A1A53591AAA1A7F8AB88FB

About this manual

The AC9100A weighing indicator instruction manual describes a weighing display for general industrial use with resistance strain-gauge load cells, including high-performance A/D conversion, digital range calibration, multiple test functions, RS232/RS485 communication boards, switch-protected parameter setting and calibration, and a wide-range switching power supply.

It covers technical specifications, installation and interface connections, function settings, calibration, external inputs and outputs, maintenance, and accessories. Calibration is required before first use or after replacing a sensor or indicator. This manual is written in Chinese.

What's inside

  • Technical specifications
  • Installation and interface connection
  • Function settings
  • Calibration
  • External input/output
  • Maintenance
  • Accessories
  • Front panel
  • Rear panel
  • Sensor connection

Specifications

Power supply (AC)85-265 V, 50/60 Hz, 8 W
Power supply (DC)18-36 V, 8 W
Sensor excitationDC 10 V, 150 mA
Minimum sensitivity0.25 uV/d
Display6-digit 7-segment red LED
Analog output options4-20 mA, 0-5 V, 0-10 V
Parallel output optionsBCD (OC/OE), BIN (OC/OE)

Frequently asked questions

Does the AC9100A need calibration before first use?

Yes. The indicator must be calibrated before first use, and also after replacing a sensor or the indicator.

What power supply can the AC9100A use?

It can use AC 85-265 V or DC 18-36 V.

What should be checked if the sensor input zero voltage is too low?

Check the sensor wiring.

What error occurs if a calibration weight is not an integer multiple of the division spacing?

The calibration weight value and division spacing are not an integer multiple; reload weights so the calibrated value is at least 100 divisions.