Installation Instructions, includes the features and characteristics of the product
This Kohler installation instruction sheet covers the Aleo widespread touchless lavatory faucet, model K-26800T-CP. It opens with ten preparation notes, including flushing the supply pipes, observing local plumbing and building codes, shutting off the water supply, and keeping the sensing eye away from strong ultraviolet or electromagnetic fields. A short operating section explains the handle movement for hot and cold water and the hand-over-sensor actuation.
The document then shows the rough-in dimensions and valve assembly drawing, lists the technical parameters, and gives illustrated installation steps with numbered parts: the faucet spout, the water drain assembly, the control valve assembly and the sensor assembly. It notes that the manual contains important installation, maintenance and cleaning information that should be passed on to the user. This manual is written in Chinese.
| Power | DC, 2 AA size alkaline batteries (LR06×2) |
|---|---|
| Inspection Duration | ≤0.35 s |
| Turn off Delay of Valve | ≤0.35 s |
| Overtime Water Control | Auto stop water supply over 4 min |
| Ambient Temperature | 1~55 ℃ |
| Supply Water Temperature | 0.5~71 ℃ |
| Supply Water Pressure | 0.05~0.86 MPa |
It runs on DC power from two AA size alkaline batteries (LR06×2).
With the handle in the open position, put your hand in the sensing range above the sensor head and water flows out.
The water supply pipes must be flushed thoroughly to remove debris; the water source should be tap water or potable water.
The overtime water control automatically stops the water supply after more than 4 minutes.