Ultrasonic open channel flow meter, used with weir to measure the flow rate of water in the open channel. It is mainly used to measure the flow rate of sewage outlet of sewage plant, enterprise and institution, urban sewer and channel in agricultural water conservancy.
This manual provides instructions for installing and operating the Meacon U-MIK-LMQ-DYCN3 ultrasonic open channel flow meter. It explains how to set up the device with various types of weirs (triangular, rectangular, trapezoidal, and Parshall flumes) and configure parameters like 4mA and 20mA flow values. The device measures liquid level using ultrasonic technology and calculates flow based on the weir type and dimensions. Technical specifications include measurement ranges, accuracy, and communication protocols.
The manual also covers troubleshooting, error handling, and communication protocols such as MODBUS. It includes tables for weir dimensions and formulas for calculating flow based on water level, with specific instructions for each weir type. This manual is written in Chinese.
| Measurement Range | 0.1 L/s to 99999.99 m³/h |
|---|---|
| Cumulative Flow | Up to 4290000000.00 cubic meters |
| Level Measurement Range | 1m, 3m, 5m (customizable) |
| Level Accuracy | 0.5% or 3mm (whichever is larger) |
| Flow Accuracy | 1–5% for Parshall flumes and triangular weirs, 10% for rectangular weirs |
| Output | 4–20mA/510Ω load |
| Power Supply | 220V AC ±15% 50Hz or 24V DC (optional) |
| Display | Chinese LCD |
| Communication | Optional 485/232 with MODBUS protocol |
| Protection Rating | Display IP65, Probe IP68; Display IP64, Probe IP68 |
The device measures the liquid level using ultrasonic technology and calculates flow based on the weir type and its dimensions.
Accuracy is 1–5% for Parshall flumes and triangular weirs, and 10% for rectangular weirs.
The device supports optional 485/232 communication with MODBUS protocol.