Chinese user manual for the Meacon U-PDCLDG-MKCN7 magnetic flowmeter covering installation, wiring, operation, and technical specifications.
This manual provides detailed instructions for the Meacon U-PDCLDG-MKCN7 magnetic flowmeter, including safety guidelines, product description, installation steps, electrical connections, startup procedures, and operation instructions. It also contains technical parameters, material selections, and performance data for both integrated and split‑type models.
The document includes wiring recommendations such as a 2 kΩ, 0.5 W pull‑up resistor for pulse output, and specifies power requirements, protection ratings, and output options (4‑20 mA, pulse, frequency). It is intended for trained personnel responsible for installing, configuring, and maintaining the flowmeter in industrial applications. This manual is written in Chinese.
| Measurement range (pipe size) | DN15~DN450 |
|---|---|
| Protection rating (converter) | IP65 |
| Protection rating (sensor) | IP65 / IP68 |
| Power supply voltage | 100~240VAC, 22VDC~26VDC |
| Power consumption | Maximum 15 VA |
| Current output range | 4~20 mA |
| Measurement accuracy (flow speed ≥1 m/s) | ±0.5 % |
| Operating temperature (sensor) | -25~180 °C |
| Maximum pressure rating | 1.6 MPa |
A 2 kΩ, 0.5 W resistor is recommended for the pull‑up resistor on the pulse output line.
The converter unit has an IP65 protection rating.
The flowmeter can output a current signal in the range of 4 mA to 20 mA.
No, the product is prohibited from use in explosion‑proof (防爆) environments.