Meacon U-DCSDS-MKCN2 Ultrasonic Distance Sensor User's Manual

This manual covers installation, wiring, parameter modification via serial port or LCD menu, and troubleshooting for the Meacon U-DCSDS-MKCN2 ultrasonic…


Meacon U-DCSDS-MKCN2 Ultrasonic Distance Sensor User's Manual - cover page
Brand
Meacon
Document type
User Manual
Language
Chinese
Pages
16
File format
PDF
File size
1.7 MB
Published
12 October, 2026
Updated
12 October, 2026
MD5 checksum
90B1F94C483DAB838A79CD883210572A

About this manual

The document provides a user guide for the Meacon U-DCSDS-MKCN2 ultrasonic distance sensor. It details the operating principles of non-contact measurement using sound waves and lists key features such as high resolution, short response time, and multiple output options including analog (4~20mA), switch quantity, and RS232/485 communication. This manual is written in Chinese.

What's inside

  • Product Introduction
  • Ultrasonic Measurement Principle
  • Main Technical Indicators
  • Installation Guide
  • Wiring Methods
  • Signal Description
  • Serial Port Parameter Modification
  • LCD Menu Operation
  • Error Phenomena and Solutions

Specifications

Measuring Range0.1~0.5m, 0.15~1m, 0.3~3m, 0.4~5m, 0.5~6m
Resolution3mm or 0.1%
Response Time<200ms
Emission Angle20°
Power Supply24V (±15%) 120mA
Operating Temperature-20~+60℃
Protection RatingIP65 (custom IP67 available)

Frequently asked questions

What is the default password for menu locking?

The initial password is 25.

How do I connect the power lines?

Connect the red wire to 24VDC+ and the black wire to 24VDC–.

What causes the status indicator light to flash red?

It indicates that the measured distance exceeds the sensor's range.