This manual covers installation, wiring, parameter modification via serial port or LCD menu, and troubleshooting for the Meacon U-DCSDS-MKCN2 ultrasonic…
The document provides a user guide for the Meacon U-DCSDS-MKCN2 ultrasonic distance sensor. It details the operating principles of non-contact measurement using sound waves and lists key features such as high resolution, short response time, and multiple output options including analog (4~20mA), switch quantity, and RS232/485 communication. This manual is written in Chinese.
| Measuring Range | 0.1~0.5m, 0.15~1m, 0.3~3m, 0.4~5m, 0.5~6m |
|---|---|
| Resolution | 3mm or 0.1% |
| Response Time | <200ms |
| Emission Angle | 20° |
| Power Supply | 24V (±15%) 120mA |
| Operating Temperature | -20~+60℃ |
| Protection Rating | IP65 (custom IP67 available) |
The initial password is 25.
Connect the red wire to 24VDC+ and the black wire to 24VDC–.
It indicates that the measured distance exceeds the sensor's range.