Qingzhi LCT, MCT, HCT Series Current Sensor Instruction Manual

Qingzhi current sensor has the characteristics of high accuracy, high linearity, high stability, high resolution, low temperature drift, low zero drift, low noise, low power consumption, fast response, wide bandwidth, strong anti-interference and high sensitivity. It is widely used in electric motor and inverter drive, consumer electronics and household appliances, generator (set), LED lighting and power supply, new energy vehicles and charging piles, new energy power generation storage and inverter, aviation and rail transit high-speed railway, robots, electric tools, health and medical devices, NDT, industrial equipment and other fields.


Qingzhi LCT, MCT, HCT Series Current Sensor Instruction Manual - cover page
Brand
Qingzhi
Category
sensor
Document type
User Manual
Language
Chinese
Pages
11
File format
PDF
File size
535 KB
Published
30 October, 2023
Updated
30 October, 2023
MD5 checksum
57F18A105888E27A7F542BC46DB27127

About this manual

This manual describes the Qingzhi LCT, MCT and HCT series current sensors, including product overview, features, industry applications, operating status, parameter tables, dimensions, wiring and precautions.

It also provides pin definitions, wiring diagrams, a test-current calculation formula and safety precautions for installation and use. This manual is written in Chinese.

What's inside

  • Product overview
  • Product features
  • Industry applications
  • Operating status
  • Parameter table
  • Dimensions
  • Wiring
  • Precautions

Specifications

LCT200 specificationsRated input ±200 A DC / 141 A AC; overload ±240 A DC; ratio 2000:1; output ±0.1 A; voltage ±15 V; accuracy 0.1%; bandwidth 100 kHz; power ±130 mA; measuring resistance 10 Ω; aperture 20 mm
LCT500 specificationsRated input ±500 A DC / 354 A AC; overload ±600 A DC; ratio 2000:1; output ±0.25 A; voltage ±15 V; accuracy 0.1%; bandwidth 100 kHz; power ±280 mA; measuring resistance 4 Ω; aperture 35 mm
MCT200 specificationsRated input ±200 A DC / 141 A AC; overload ±240 A DC; ratio 2000:1; output ±0.1 A; voltage ±15 V; accuracy 0.05%; bandwidth 100 kHz; power ±130 mA; measuring resistance 10 Ω; aperture 26 mm
MCT500 specificationsRated input ±500 A DC / 354 A AC; overload ±600 A DC; ratio 1500:1; output ±0.333 A; voltage ±15 V; accuracy 0.05%; bandwidth 100 kHz; power ±363 mA; measuring resistance 2 Ω; aperture 38 mm
MCT1000 specificationsRated input ±1000 A DC / 707 A AC; overload ±1200 A DC; ratio 1500:1; output ±0.67 A; voltage ±15 V; accuracy 0.05%; bandwidth 100 kHz; power ±700 mA; measuring resistance 1.5 Ω; aperture 38 mm
MCT1500 specificationsRated input ±1500 A DC / 1060 A AC; overload ±1600 A DC; ratio 1000:1; output ±1.5 A; voltage ±15 V; accuracy 0.05%; bandwidth 100 kHz; power ±1030 mA; measuring resistance 1 Ω; aperture 38 mm
HCT200 specificationsRated input ±200 A DC / 141 A AC; overload ±240 A DC; ratio 1000:1; output ±0.2 A; voltage ±15 V; accuracy 0.02%; bandwidth 300 kHz; power ±230 mA; measuring resistance 10 Ω; aperture 26 mm
HCT500 specificationsRated input ±500 A DC / 354 A AC; overload ±600 A DC; ratio 1500:1; output ±0.333 A; voltage ±15 V; accuracy 0.02%; bandwidth 300 kHz; power ±363 mA; measuring resistance 3 Ω; aperture 38 mm
HCT1000 specificationsRated input ±1000 A DC / 707 A AC; overload ±1200 A DC; ratio 1500:1; output ±0.67 A; voltage ±15 V; accuracy 0.02%; bandwidth 300 kHz; power ±700 mA; measuring resistance 1.5 Ω; aperture 38 mm
Working power supply±DC dual supply, DC (15±0.8) V
Operating environment-40 to 80 °C, 20 to 80% RH

Frequently asked questions

What happens if the input current exceeds the sensor's rated range?

The sensor enters overload mode and its output current is no longer proportional to the input current; normal proportionality returns when the input current is back within the rated range.

What are the pin functions?

Pin 1 is +15 V supply, pin 2 is -15 V supply, pin 3 is I_Output and pin 4 is GND.

What precautions should be followed when using the sensor?

The secondary side must not be open during operation, one end of the secondary side must be grounded, and incorrect connection of control terminals can damage the internal circuit.

How is the primary current calculated during testing?

The primary current is calculated as Ip = Kn × Is = Kn × (Ur / RM).

Download PDF (535 KB)