This manual introduces the AT-8225BGA rework station's functions, features, usage methods, safety precautions, etc.
The Atten AT-8225 BGA Rework Station manual describes a two-zone design with upper hot-air heating and lower IR heating, independent upper and lower temperature control, 8 heating and cooling segments, and storage for 10 groups of temperature data. It covers safety precautions, structure and functions, setting and operation, and usual temperature parameters for lead and lead-free BGA chips.
Specifications include 2600 W total power, an AC220V±10% 50/60Hz power supply, K thermocouple closed-loop control with ±2 degree accuracy, PCB size from 20×20 mm to 300×300 mm, BGA chip sizes from 5×5 to 55×55, minimum chip spacing of 0.15 mm, and a net weight of about 14.5 kg. The text also describes V-groove PCB positioning, a removable fixture, an emergency stop switch, and automatic power-off protection.
| Power | 2600 W total; top heater 800 W; bottom heater 1800 W |
|---|---|
| Power supply | AC220V±10%, 50/60 Hz |
| Dimensions | L470 × W370 × H500 mm |
| Temperature control | K thermocouple (K sensor), closed loop |
| Temperature accuracy | ±2 degrees |
| PCB size | Max 300 × 300 mm; Min 20 × 20 mm |
| BGA chip size | 5×5 to 55×55 |
| Minimum chip spacing | 0.15 mm |
| Net weight | About 14.5 kg |
It requires AC220V±10%, 50/60 Hz.
The manual states a temperature accuracy of ±2 degrees.
It supports PCB sizes from 20×20 mm minimum to 300×300 mm maximum.
The manual says to wear heat-proof gloves and never touch the high-temperature zone.