XKC-Y28A-NO Intelligent non-contact liquid level sensor is a smart liquid level sensor produced by Xingkechuang Technology Co., Ltd. It has a wide range of applications and is mainly used in industrial, agricultural, chemical, environmental protection, medical and other fields.
This instruction manual covers the XKC-Y28A-NO intelligent non-contact liquid level sensor made by Shenzhen XingKeChuang Technology Co., Ltd. The sensor is designed for non-metallic pipes with an outer diameter of 10 mm or less, detecting liquid through the pipe wall without contact, so it is not corroded by strong acids, alkalis or other corrosive liquids. It uses an inductive capacitance method and is available with relay normally open output (XKC-Y28A-NO), normally closed output (NC) or RS485 output.
The manual describes the product overview, features, applications, parameters and model selection, then explains installation on a pipe with the spring clip, sensitivity adjustment with a small screwdriver, and the wiring diagram for the relay NO output depending on whether the black wire is connected to VCC or GND. It ends with precautions about liquid viscosity, temperature and outdoor use, a troubleshooting table and the warranty terms. The document is version XKC-Y28A-NO-V1.6 and runs to 10 pages. This manual is written in Chinese.
| Product model | XKC-Y28A-NO |
|---|---|
| Supply voltage (Vin) | 5V, 12V, 24V |
| Output mode | Normally open |
| Current | 13mA |
| Output current | DC24V/2A |
| Response time | 500mS |
| Working temperature | -20~105℃ |
| Applicable pipe diameter range | Outer diameter of pipe 5-10 mm |
| Liquid level accuracy | ±1.5mm |
| Humidity | 5%~100% |
| Line length | 500MM (±10MM); bulk orders can be customized |
| Material | PC-V0 fireproof material |
| Waterproof performance | IP67 |
| Safety standard certification | CE |
| Environmental protection certification | ROHS2.0 |
| Terminal model | XH2.54-4P |
It is suitable for pipes with an outer diameter of 5 mm to 10 mm, and the diameter must not exceed 11 mm.
Use a small screwdriver on the sensitivity knob: turn counterclockwise to increase sensitivity, clockwise to lower it.
The sensor can be powered from 5V, 12V or 24V, and separate models are listed for each voltage.
It penetrates non-metallic containers and pipes such as plastic, glass and ceramic, including curved, arc and cylindrical shapes.