The XKC-C352 intelligent non-contact liquid level controller from Shenzhen XingKeChuang Technology Co., Ltd. uses the low-level liquid level sensor to send a low-level alarm signal, which triggers the C352 controller to close the relay to start the water pump to add liquid level, and the high-level liquid level sensor sends a signal when the liquid level reaches a certain height. The C352 controller disconnects the relay and automatically stops the water pump to work, thereby realizing the automatic control of the container liquid level and keeping the container liquid level stable.
This is the Chinese user manual for the XingKeChuang XKC-C352 intelligent non-contact liquid level controller, the AC180V-250V version (document version V1.6). The controller works together with XKC-Y25 liquid level sensors to switch a pump on and off and keep a tank level within a set range; it is available in versions XKC-C352-1P through XKC-C352-4P with one to four sensors.
The manual describes the product, lists its electrical parameters, gives the signal-input to relay-output table, explains automatic fill and drain control, manual/automatic switching with the K1 key, and the inlet-pipe, overflow and low-level sensor alarm functions. It also includes mounting notes, wiring diagrams for the 1P to 4P versions, dimensions and product photos, troubleshooting notes and warranty terms. This manual is written in Chinese.
| Model | XKC-C352 |
|---|---|
| Input voltage | AC180V-250V, 50/60Hz |
| Operating current | ≤110 mA; quiescent current ≤20 mA |
| Resistive load power | 1.6 kW or less |
| Inductive load power | 1 kW or less |
| Alarm output | 800W (resistive load), normally open/normally closed output |
| Output type | Normally open / normally closed output |
| Input signals | Low-level sensor signal input; high-level sensor signal input |
| Sensor interface voltage | DC 12V |
| Operating temperature | -20 to 105 °C |
| Dimensions | 115 x 90 x 40 mm |
It works with XKC-Y25 liquid level sensors, which provide the low and high level signals that control the pump relay.
The AC180V-250V selection includes XKC-C352-1P, -2P, -3P and -4P, supplied with 1, 2, 3 or 4 sensors respectively.
If no water is detected within 10 to 30 seconds, the load output relay opens to stop pumping and the alarm output relay closes.