Geotech BP Controller 300PSI Installation and Operation Manual

This manual provides instructions for installing and operating the Airbag Pump Controller 300PSI (BP Controller).


Geotech BP Controller 300PSI Installation and Operation Manual - cover page
Brand
Geotech
Category
Other Electronics
Document type
User Manual
Language
Chinese
Pages
23
File format
PDF
File size
1.2 MB
Published
29 October, 2023
Updated
29 October, 2023
MD5 checksum
45716E5AC4B6396B13BF35FEC650A898

About this manual

The Geotech BP Controller 300PSI is an electronic logic-controlled device designed to manage high-pressure pumps for slow, low-flow sampling. It features an automatic pressure relief regulator and a high-pressure solenoid valve, allowing it to draw samples from depths up to 690 feet (210 meters). The controller connects to any bladder pump using a simple push-to-connect hose adapter and includes a user-friendly interface to display status and battery levels.

The system is housed in a heavy-duty carrying case for mobility and durability. It operates using a cycle of pressurizing the pump to push liquid through the discharge line and depressurizing to allow the pump to refill via hydrostatic pressure. Users can adjust fill and discharge times via dials, and the unit is compatible with water level meter (WLM) devices via a drop cable connection. This manual is written in Chinese.

What's inside

  • System Description
  • System Installation
  • System Operation
  • System Maintenance
  • System Specifications
  • System Schematic
  • Parts and Accessories
  • EC Declaration of Conformity

Specifications

Model Number81150042
Max Input DC Power0.5 ~ 13.8 V DC
Max Input AC Power105 ~ 130 V AC
Operating Pressure Range10 ~ 300 PSI
Max Air Input Pressure350 PSI
Max Operating Depth690 feet (210m)
Discharge Timer Range10 ~ 120 seconds
Fill Timer Range10 ~ 120 seconds
Battery Life1300 cycles, 20 hours
Operating Temperature32° ~ 158°F (0 ~ 70º C)
Weight15 lbs (6.8 kg)

Frequently asked questions

What is the maximum operating depth of the controller?

The controller can draw samples from a depth of up to 690 feet or 210 meters.

What is the maximum air input pressure?

The maximum air input pressure is 350 PSI (24 bar).

How long does the battery last on a full charge?

The 12V 8AH battery provides a life of 1300 cycles or 20 hours at 30-second fill and discharge timers.

What is the required charging voltage for the battery?

The battery needs to be charged to at least 12.8V before the controller can resume cycles.