This document lists the parts list for Sloan® Flushometer
This document provides a detailed parts list for Sloan flushometer models, including item numbers, part descriptions, and specifications for components like handles, control stops, and vacuum breaker assemblies. It also includes troubleshooting guidance for common issues such as no flush, insufficient water volume, or chattering noise. Maintenance instructions emphasize using genuine Sloan parts and avoiding sealants or toothed tools to preserve finish. The guide covers repair kits, diaphragm assemblies, and adjustment procedures for flush volume and pressure.
| Model Variants | A-3-A, B-73-A, H-710-A, V-500-AA |
|---|---|
| Flush Volume Options | 1.0 gpf/3.8 Lpf to 3.5 gpf/13.2 Lpf |
| Gasket and Ring Sizes | 1-1/2”, 1-1/4”, 1”, 3/4” |
Models include A-3-A, B-73-A, H-710-A, and V-500-AA.
Check if the control stop or main valve is closed, replace a worn handle assembly, or replace the inside parts kit if the relief valve is worn.
Use only mild soap and water; avoid abrasive or chemical cleaners including chlorine bleach.