This is the user manual for C-123LW. It introduces the product functions, installation methods and troubleshooting methods.
This document provides supplemental instructions for installing and troubleshooting the Aiphone C-123LW Dual Master ChimeCom system, which includes chime, communication, and door release for one door and two inside locations. It covers wiring diagrams, component compatibility, power requirements, and modifications for magnetic locks. The guide also includes troubleshooting tips for common issues such as feedback, weak chime, or incorrect power connections.
Installation requires separating intercom and door release wiring, using shielded cables, and ensuring each master station has its own power source. Modifications for magnetic locks involve changing the door release switch from Normally Open to Normally Closed using a capacitor and diode.
| Master Station | C-ML/A |
|---|---|
| Compatible Door Stations | C-D, LE-D, LE-DA, LE-SS-1G, LE-SS, LE-SSR, LS-NVP/C |
| Power Source | SKK-620B or 4 "C" batteries |
| Door Release Wire | Separate 2-conductor wire from intercom wiring |
No, do not install both power sources on one master station.
Remove the back chassis, move the wire from the NO contact to the NC contact, and resolder the connection.
Wait approximately 15 seconds, or until the masters turn off automatically, then communication can continue normally.