This tech tip is for rapid diagnosis of proportion rocker controllers, including dual-axis and single-axis proportion rocker controllers. It introduces how to use a multimeter, jumper wires, batteries and other electronic components to quickly diagnose controller faults. It also introduces safety rules and precautions.
This document provides step-by-step instructions for diagnosing Sauer Danfoss proportional joystick controllers (models 101173-101175) installed on Genie aerial platforms. It covers wiring layouts, voltage measurements, and LED behavior to identify controller faults. Safety rules and required tools are included to ensure proper handling during diagnostics.
The guide explains how to connect diagnostic tools, measure power and output voltages, and interpret LED indicators for controller status. It also specifies compatible Genie models and voltage ranges for accurate testing.
| Controller Models | 101173, 101174, 101175 |
|---|---|
| Output Voltage at Center Position | Half of input voltage |
| LED Forward Voltage Rating | 4.7 to 5.0 volts |
When the joystick is centered, no LEDs should illuminate. If all LEDs glow, the controller’s LED forward voltage rating is lower than the power supply voltage.
Models including Z135, S40/45 12510, S60/65/HC 14782, S80/85 5520, S100/105 420, and S120/125 1617 use these controllers.