Key facts
- Manuals
- 4
- Languages
- EN
- Last added
- 2026-10-03
Featured Sauer Danfoss manuals

Sauer‑Danfoss OMS OMT OMV Orbital Motors Technical Information
The document provides detailed technical information for the OMS, OMT and OMV series of orbital motors manufactured by Sauer‑Danfoss. It includes specifications such as displacement, speed, torque, output power, as well as variant options, mounting configurations, and dimensional data.
The data is organized into sections covering speed‑torque‑output charts, version and code number tables, shaft‑seal pressures, oil‑flow characteristics, permissible shaft loads, function diagrams, and installation guidelines for the various motor variants.
Covers: Speed, torque and output · Version and code numbers · Technical data · Max. permissible shaft seal pressure · Pressure drop in motor · Oil flow in drain line

Sauer-Danfoss Series 90 Axial Piston Pumps Technical Information
The Series 90 axial piston pumps and motors are compact, high‑power‑density units intended for closed‑circuit hydraulic applications. They use a parallel axial piston/slipper design with a tiltable swashplate to vary displacement and can operate bidirectionally.
This technical information document includes general descriptions, detailed specifications (displacement, flow, torque, weight, speed, pressure), operating limits, fluid requirements, available control options, auxiliary mounting pad data, and installation drawings for the full range of frame sizes.
Covers: General Description · Technical Specifications · Operating Parameters · Features and Options · Control Options · Installation Drawings

Sauer-Danfoss MCV116 Pressure Control Pilot Valve User Manual
The MCV116 Pressure Control Pilot (PCP) Valve is a low‑cost, stand‑alone, closed‑loop valve used in electro‑hydraulic systems such as construction, farming, material handling, marine, mining and industrial equipment. It converts a DC control current into a proportional hydraulic differential pressure via a torque‑motor and double‑nozzle flapper mechanism.
The valve includes optional environmental connectors, intrinsic safety features, and can operate in both open‑loop and closed‑loop configurations. Detailed specifications cover scale factor, coil resistance, saturation current, temperature and pressure limits, as well as environmental data for shock, vibration and humidity. Wiring diagrams and connector options are provided for various installation scenarios.
Covers: Description · Theory of Operation · Internal Workings Schematic · Features and Dimensions · Frequency Response · Scale Factor and Load Pressure Droop

Sauer-Danfoss Series 45 Axial Piston Open Circuit Pumps Technical Information
The Series 45 family is a line of variable‑displacement axial piston pumps designed for open‑circuit hydraulic applications in mobile equipment. The document provides detailed specifications for the J‑frame units (45, 51, 60, 65, and 75 cm³) and outlines design features, performance data, and installation guidance.
Key data include displacement ranges, speed limits, pressure ratings, and available control strategies such as load‑sensing, pressure‑compensated, and remote pressure‑compensated controls. Installation drawings and mounting options are also provided.
Covers: Overview · Design · High performance · Latest technology · Reliability · Typical applications
Latest Sauer Danfoss manuals
Sauer‑Danfoss OMS OMT OMV Orbital Motors Technical Information
Product Leaflet 32 pages · 5.2 MB · ENTechnical data, dimensions and variant options for Sauer‑Danfoss OMS, OMT and OMV orbital motor series.
Sauer-Danfoss Series 90 Axial Piston Pumps Technical Information
Product Leaflet 68 pages · 4.8 MB · ENProvides technical specifications, operating parameters, features, options, and installation drawings for Sauer‑Danfoss Series 90 axial piston pumps.
Sauer-Danfoss MCV116 Pressure Control Pilot Valve User Manual
User Manual 17 pages · 2.2 MB · ENThe MCV116 is a torque‑motor actuated pressure control pilot valve that provides proportional hydraulic output from a DC input for electro‑hydraulic systems.
Sauer-Danfoss Series 45 Axial Piston Open Circuit Pumps Technical Information
Datasheet 44 pages · 2.6 MB · ENTechnical information for Sauer‑Danfoss Series 45 axial piston open‑circuit pumps, covering specifications, control options, and installation details.
Which document do I need?
User Manual
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Datasheet
Ratings, dimensions and ordering codes, for selection and design work.
Questions answered in Sauer Danfoss manuals
What is the maximum permissible shaft seal pressure for OMS motors?
The maximum permissible shaft seal pressure is listed under the heading “MAX. PERMISSIBLE SHAFT SEAL PRESSURE”.
From: Sauer‑Danfoss OMS OMT OMV Orbital Motors Technical Information
What is the minimum input speed for Series 90 pumps?
The minimum input speed is 500 rpm.
From: Sauer-Danfoss Series 90 Axial Piston Pumps Technical Information
Which frame sizes are available for the Series 90 pumps?
Frame sizes 042, 055, 075, 100, 130, 180 and 250 are offered.
From: Sauer-Danfoss Series 90 Axial Piston Pumps Technical Information
What type of electrical input does the MCV116 accept?
The PCP accepts a DC current and produces a proportional hydraulic differential pressure.
From: Sauer-Danfoss MCV116 Pressure Control Pilot Valve User Manual
How is the null adjustment performed on the valve?
Remove the adjustment screw and turn it with a 3/32‑inch hex key to set the null.
From: Sauer-Danfoss MCV116 Pressure Control Pilot Valve User Manual
What is the maximum operating pressure of the pumps?
The pumps are rated for a continuous pressure of 310 bar (4495 psi) and a peak pressure of 400 bar (5800 psi).
From: Sauer-Danfoss Series 45 Axial Piston Open Circuit Pumps Technical Information
