This document describes how to install a Riello burner for use with Williamson Thermoflo oil boilers.
This guide provides step-by-step instructions for installing Riello F3/F5 oil burners in Williamson Thermoflo oil boilers. It covers harness connection, mounting methods, nozzle and turbulator settings, and electrical connections. Safety warnings and local code compliance are emphasized. The guide also includes technical specifications, component identification, and troubleshooting references for proper burner operation.
| Firing Rate - Effective Output | F3: 0.50 to 0.95 US GPH (70,000 to 133,000 BTU/h); F5: 0.75 to 1.65 US GPH (105,000 to 231,000 BTU/h) |
|---|---|
| Voltage | 120V 60Hz (+10% -15%) |
| Absorbed Electrical Power | F3: 155 Watts; F5: 175 Watts |
| Motor (rated) | 3250 rpm |
| Run Current | 2.2 AMP |
| Capacitor | 12.5 Microfarads |
| Pump Pressure | 130 to 200 psig |
| Primary Control | RIELLO 530 SE/C |
| Ignition Transformer | 8kV 16mA |
Fuel no heavier than #2 fuel oil.
120V 60Hz (+10% -15%).
130 to 200 psig.
RIELLO 530 SE/C.